Sump level sender blanking plate DB2 to MkII, replaces the leaky sender assembly on the tin sump, laser cut for accuracy,
Just remove the sender with the six screws, unsolder the brass ring on the inside (this is where the leaks are often from), clean off the solder on the inside & paint on the outside & tig weld or silver solder the new plate in, leak test before re-fitting the sump